Articles on Technology, Health, and Travel

Opentherm connection of Technology

They are reports that Intergas boilers have an issue with an Ope.

OpenTherm Explained. OpenTherm is a communication protocol between heating controls and the boiler to modulate the temperature flow through a heating system. This can increase the energy efficiency of a heating system whilst maintaining the desired set point temperature in the home. Here we explain how three types of heating systems operate.Open the housing by pulling the front and the base plate apart. Attach the base plate of the controller to the wall using the screws and plugs supplied. Ensure that the boiler's connecting wires are protruding through the hole in the base plate. Connect the thermostat to the boiler OpenTherm connection. T001046-C.Stevebn said: I've had a viessmann 100-w with Nest for 3 years. The Nest is connected via the opentherm connections so it can modulate the boiler. I spoke to viessmann and they said you can't have both Nest installed on opentherm and the outside temperature sensor installed, (so I didn't install the temp sensor).- Verify that your heating system supports OpenTherm. - Make sure that the Heat Link is correctly wired. - If your system does not support OpenTherm, you will need to select On/Off boiler control instead of OpenTherm. N80 error: OpenTherm requires a wireless connection but wireless isn't detected. - Restart the Heat Link.Hi All, I'm looking to wire up our Ecotec 937 plus with Opentherm and Evohome. So far I can source the VR33 module and have located the X31 interface on the PCB where this should be plugged in. Unfortunately it appears to have another connection already plugged into this serving the shift load storage tank.OpenTherm protocol is a point-to-point protocol: only 1 Boiler must be connected to a MB-OTG; the connection of two or more Boilers on the same MB-OTG may cause damage to the Boiler and/or the Gateway interface.OpenTherm Thermostat Shield. There's a variety of OpenTherm thermostats out there. Most smart thermostats cost from €100 to €300, which is quite expensive. This article describes how to build your own smart OpenTherm Thermostat with remote control for a cheap price and without any monthly costs. We provide a simple solution, which gives you ...Connect the plugged end of the power adaptor into the 24V terminal on the gateway. 1. Page 8 Gateway terminals - OT are for OpenTherm connection to compatible boilers ON OFF Gateway terminals - R-BUS are for connection to the uSense room unit These components are low voltage - 230V will damage ON / OFF the room unit and gateway.OpenTherm connection OT OpenTherm connection OT OpenTherm connection Putting the Device into Operation Remove front cover of the transmitter and insert 2× 1.5 V AA alkaline batteries. Do not use 1.2 V rechargeable batteries. Insertion of batteries starts the thermostat and activates the display.Drayton Wiser Hub API v2 v0.0.42. This repository contains a simple API which queries the Drayton Wiser Heating sysystem used in the UK. The API functionality provides the following functionality to control the wiser heating system for 1,2 and 3 channel heat hubs The API also supports Smart Plugs and initial basic functionality for Shutter and ...OpenTherm connection OT OpenTherm connection OT OpenTherm connection Putting the Device into Operation Remove front cover of the transmitter and insert 2× 1.5 V AA alkaline batteries. Do not use 1.2 V rechargeable batteries. Insertion of batteries starts the thermostat and activates the display.OpenTherm connections in boiler Important - To avoid damage to Boiler and Thermostat, con - nect only to OpenTherm connections on boiler, do not connect to any other power source. ORT-01 ORT-10 There are some new words entering the HVAC vocabulary, OpenTherm and modulating controls. OpenTherm is an Industry Standard for Modulating controls.Opentherm to eBus bridge. I have a boiler that speaks eBUS (A Valliant protocol) and a heating system going in that speaks Opentherm. I have HomeAssistant (on a Pi 4) running as an experimental setup whilst I get my head around Home automation. Is there a way to get Homeassistant to act as a bridge between the two protocols?Copy the secret and save it somewhere. 3. Find Your HEATHUB IP. Using your router, or something else, identify the IP address of your HeatHub, it usually identifies itself as the same ID as the WiserHeatXXXXXX. Alternatively see the test_api_discovery.py file for how to use the api to discover your hub.The resulting board is designed for use with an OpenTherm-compatible Espressif ESP32 and ESP8266 firmware, providing control of compatible condensing boilers or air conditioning systems. ... It comes with programs to test the connection with your boiler, a full functioning basic thermostat example and a Arduino library designed in OSI model ...CH : Controlled by Nest which opens the CH valve via connector 3 and controls the boiler temp via OpenTherm. Valve orange wire not connected to boiler as OpenTherm replaces it. HW : Controlled by Nest which opens the HW valve via connector 6 and I assumed would control the boiler temp via OpenTherm (i.e. Call for higher boiler …Ensure that the OpenTherm connecting wires for the boiler are poking through the hole in the base plate. R000083-B 150 cm R000078-A R000058-D Ø6 mm 2. Location Opentherm Modulating room thermostat 3 31032014 - 7616664-01. 5. Connect the controller to the OpenTherm connection of the boiler,ANSWER: I wired the Drayton Wiser OP1 & OP2 connections to the opentherm connections of my Logic C30 boiler. I left my Drayton Wiser 230v relay connections wired the same so they powered my dual zone valves in the same way. I disconnected the Room/Stat connection on my boiler from my stat linking out the two pin connections on boiler.My situation: I have WiFi Thermostat (OpenTherm) in the living room. The living room thermostat is connected to the boiler and controls the demand for hot water the complete central heating network. I have radiators in several rooms with TRV’s, which are normally turned off / closed. The radiators in the living room are always open and …Access to the connection strip From the bottom of the boiler, the connection terminal for the room thermostat (1, fig. 6) or the Remote control timer (2, fig 6), as illustrated in fig. 6. FIG. 6 - Access to the terminal block 1 = Connection of the room thermostat 2 = Remote control timer connection (Opentherm)There is no specific uk version of the wired starter kit, which has digital connections. There is a uk version of the wireless receiver, which doesn’t have digital connections and an eu version, which does, and is often out of stock in the uk. This is what confuses people who want a wireless set up with a modulating connection.EPH CP4i Wireless OpenTherm Programmable Thermostat | ErP Class 6 | The EPH CP4i is an easy to install and user friendly wireless digital RF programmable room thermostat and receiver suitable for controlling one …Note: The Hub Receiver should have a wired OpenTherm® connection to the boiler. Connect Connect Connect Connect Connect RESET Connect Connect Manual Manual Manual RFRP-OT Thermostat RF1A-OT Receiver OpenTherm® Boiler OT Auxiliary switch wire from motorised valve. Title: 20190430_RFRP-OT_OTIns_JWApr 2, 2018 ... Arduino Connection: · OT1/OT2 - two wires connected to boiler regardless of polarity instead of usual thermostat · VCC(+) to Arduino 5V, GND(-) to&nbs...Pressure in the heating system. Gateway status (depending on errors and connection status) Boiler connection status via OpenTherm interface. The current temperature of the heat carrier (usually the return heat carrier) Set heat carrier temperature (depending on the selected mode) Current hot water temperature. Home Assistant integration via MQTT.Page 7 ORT-01 OpenTherm connections in ORT- 01 Wires can be crossed OpenTherm connections in boiler Important - To avoid damage to Boiler and Thermostat, connect only to OpenTherm connections on boiler, do not connect to any other power source. Page 8: Mounting Mounting... Page 9: Locking & Limiting Locking and Limiting 1.A library to interface with the OpenTherm Gateway through serial or network connection. - mvn23/pyotgwBaxi trainer Roy talks you through the benefits of wiring a boiler up using Opentherm instead the usual 240 volt switching. Demonstrated on the Baxi 600Pleas...OpenTherm is an innovative communication protocol that allows heating controls like room thermostats and modulating central heating appliances like your boiler to interact more effectively. The OpenTherm protocol sets the rules on how the boiler and thermostat communicate. It allows bidirectional information exchange that enables …Aug 20, 2022 ... ... connected using Opentherm. If you have an Opentherm connection, you will have some reconfiguring to do on the boiler, as Hive does not ...We're having a new Ideal Vogue C32 boiler fitted today and tomorrow, it has 2 OpenTherm terminals, but they're not individually marked with OT1 and OT2 (please see photo). I'm thinking of fitting a Nest 3rd Gen Thermostat, the heatlink that is supplied with the Nest has OT1 and OT2 marked and the diagram shows to connect OT1 from the Heatlink ...I also should have added - because NEST is OpenTherm compatible - and so is the Vitodens 100 - If i just wired up the OT1 and OT2 connections from NEST to the Boiler, is that all I need to wire in order for the NEST to control both CH and DHW - or are other connections required?Hello Herman, My setup uses the Nodo OpenTherm gateway (which now is version 2.3 hardware) and a NodeMCU for the WiFi connection. All documentation is on the website of the Nodo shop.OpenTherm is a 2 wire bus, you should connect the pins on the shield to corresponding pins in the boiler. Disclaimer By using this electronics project, you acknowledge and accept that there are inherent risks associated with working with electronic components, circuits, and devices.OpenTherm is an innovative communication protocol that allows heating controls like room thermostats and modulating central heating appliances like your boiler to interact more effectively. The OpenTherm protocol sets the rules on how the boiler and thermostat communicate. It allows bidirectional information exchange that enables precise ...1 Remove the OpenTherm cables from the existing controller or thermostat. 2 Remove the Communication module from the rear of the HubR. 3 Set the OpenTherm cables into the …Hi, I’m trying to setup to Opentherm Gateway integration in Home Assistant (lastest version running on Odroid C2). Mu connection parameter is socket://192.168.0.140:23. But it always says is fails to connect. If I loo…Learn about the OpenTherm protocol, a standard for communication between HVAC devices and thermostats, and its benefits and features.Ideal Logic Plus Boiler Installation with a Nest Learning Thermostat and Open Therm Controls. #Plumber #NewBoiler Take out a badly installed Worcester Bosch ...Try using the OpenTherm connection. I believe your boiler does support OpenTherm. ... Additional comment actions. Ebus/ht-bus is my boilers opentherm equivalent. I tried switching it over to OT and while it did seem to work it didn't enable water temperature control. Tado support tells me water temp control is only available on water tanks ...OpenTherm Connections Polarity free Maximum line length 50 meters Maximum cable resistance 2.5 Ohms Plastic Thermoplastic, flame retardant Transmission distance Approx. 30m in open terrain Protection rating IP30 Dimensions 135mm(L) x 90mm(W) x 33mm(D) Complies with: EN60730-1 EN 60730-2.7, EMC Directive 2014/30/EU, LVD Directive 2014/35/EU, R&TTEBaxi trainer Roy talks you through the benefits of wiring a boiler up using Opentherm instead the usual 240 volt switching. Demonstrated on the Baxi 600Pleas...OpenTherm integration is based on OpenTherm protocol specification v2.2 and works with all OpenTherm compatible boilers. OpenTherm protocol requires a simple low voltage two-wire connection to the boiler, but voltage levels (7..15V) still much higher than ESP8266 levels, which requires OpenTherm Adapter.The slave interface drives the current on the OpenTherm connection and measures the voltage. Control unit (IC1, R15, SV2, SV3, and JP1) The PIC16F88 or PIC16F1847 is the central intelligence of the OpenTherm gateway. The reset line is normally held high by a resistor connected to VCC. Several of the I/O pins are made available via headers.Tado is compatible with OpenTherm and theoretically compatible with Saunier Duval's proprietary eBus. Since I purchased the OpenTherm extension card, I used the OpenTherm connection to connect the Tado thermostat.May 2, 2023 · Installation of OpenTherm connections. To connect using the OT terminals. Connect the OpenTherm connectors on the boiler to the OT terminals on the gateway D o not connect 230V to these terminals or it will damage the gateway; These will communicate with the boiler to control the heating and other functions; These connections can be made using ...Please note timed Hot Water is disabled when using the Opentherm connection as most Opentherm boilers control the Hot Water on demand. Please contact Resideo Honeywell Home for any queries regarding Opentherm compatibility issues. Region. EMEA. Files (0) Show actions for Files.Opentherm wired or wireless receiver? BOG73 . March 2022. There is any functionality difference in opentherm mode if the conection is made directly (wired) or wireless receiver? If wireless receiver is not used and therefore will not comand the boiler via opentherm but thermostat will do this by direct connection (wired) the opentherm protocol ...The EMS bus connections are labelled B & B on ST19. Do make sure this is the right manual for your boiler though as there are different manuals for different ages of boiler. For my original setup it was easy as I could see where the FW100 weather compensating controller was wired in and just connect the interface board in parallel.Page 1 VIESMANN Installation and service instructions for contractors Mixer extension kit OpenTherm mixer extension kit For Vitodens 100-W, 111-W and 050-W Mixer extension kit Please keep safe. 5837721 GB 11/2018... Page 2 Safety instructions Safety instructions Please follow these safety instructions closely to prevent accidents and material ...ESP32 OpenTherm Wi-Fi Thermostat Sketch. Download sketch from DIYLESS github repository esp32-wifi-thermostat. Paste your auth token, specify WI-FI SSID, WI-FI password and update pins configuration according to which module you want to use ESP8266 or ESP32. Connect WeMos D1 Mini or WeMos D1 Mini ESP32 module …My boiler's OpenTherm wired connection is the same point as the dry contact thermostat connection . Because my boiler is in an unheard area my plumber recommended an external frost thermostat that kicks in at about 5C. If I use OpenTherm to nest and the frost thermostat kicks in, what will happen?Blue square = Bosch connection, red square = OpenTherm module connections. So this was the old working connection with an old non modulating thermostat. The Red square in the picture above shows the pins connected to the OpenTherm module. Bosch calls this the OTM1 in their manual. OpenTherm Module (OTM1)OpenTherm se encarga de regular la temperatura del agua cuando está nuestra caldera encendida. Trabajan de un modo distinto al de las calderas convencionales que solo tienen la función de apagado / encendido. Por tanto solo reciben esa orden, van al 0% o al 100% de potencia. Eso quiero decir que cuando llega a la temperatura deseada esta se ...Opentherm connection multi zone. mattspeke . September 2022. Hi, I have a 2 zone system currently using 2 wired thermostats is relay mode. These thermostats are connected to SRVs in most rooms. Can I connect the 2 wired thermostats to the boiler using the digital opentherm connections. My boiler is opentherm compatible. Hello, I'm pretty new in Home Assistant. Before I Jul 23, 2017 ... OpenTherm protocol. The Nest geneProvide TCP/IP relay server to allow othe

Health Tips for Info soci vacanze di natale 201314.htm

The integration of Brink Renovent HR with openHAB leverag.

OpenTherm Library for HVAC system control communication using Arduino and ESP8266/ESP32 hardware. OpenTherm Library is based on OpenTherm protocol specification v2.2 and works with all OpenTherm compatible boilers. ... OpenTherm protocol requires simple low voltage twowire connection to boiler, but voltage levels (7..15V) still much higher than ...Check out my new video https://www.youtube.com/watch?v=p77iH66vcUoBoiler Plus ,How to connect your Nest Thermostat Using OpenTherm. Ideal Vogue installation ...Learn about the OpenTherm protocol and interface specifications for modulating HVAC appliances and room thermostats.The receiver can work with the OpenTherm protocol or with the On-Off contact. Page 34 The gateway must be installed inside the building and should not be shielded by any metal enclosures. OpenTherm option (a fig. 1): Connect the two red wires with label OTBus, coming from the receiver, to the boiler where the OpenTherm connection is foreseen.OpenTherm se encarga de regular la temperatura del agua cuando está nuestra caldera encendida. Trabajan de un modo distinto al de las calderas convencionales que solo tienen la función de apagado / encendido. Por tanto solo reciben esa orden, van al 0% o al 100% de potencia. Eso quiero decir que cuando llega a la temperatura deseada esta se ...OpenTherm is a digital language that puts the boiler and thermostat in constant communication. This gives the boiler more information about the temperature of the room, which it can use to run more efficiently. Most modern condensing boilers are modulating. This means they can run at more than one heating output (the output, otherwise known as ...OpenTherm Adapter is minimized version of Arduino Controller and its compatible with 5V and 3.3V controllers like ... ESP8266 and other similar controllers. OpenTherm protocol requires simple low voltage twowire connection to boiler, but voltage levels (7..15V) still much higher than Arduino/ESP8266 levels, which requires OpenTherm ...Connect to OpenTherm Gateway directly by USB connection; Provide TCP/IP relay server to allow other OpenTherm monitor software connection by this instance (when direct USB connection is used) Where ; Support me. If you like my work, please feel free to provide a personal donationConnect to OpenTherm Gateway directly by USB connection; Provide TCP/IP relay server to allow other OpenTherm monitor software connection by this instance (when direct USB connection is used) Where; Support me. If you like my work, please feel free to provide a personal donationADHD and depression can often occur together. Learn about shared symptoms and risk factors for comorbid ADHD and depression. ADHD and depression are both common and share some symp...Discuss Nest Thermostat can't detect OpenTherm connection on a Baxi boiler in the USA area at PlumbersForums.net. PedroM. Messages 3. Nov 25, 2021 #1 Hi, I live in Lisbon and I've just installed a Baxi combi boiler and connected it with a Google nest 3rd generation thermostat as the picture below depicts.Product Details. Drayton Digistat RF901 provides wireless connection to the boiler and has relay or OpenTherm outputs. Provides flexibility with universal operation and optional smartphone control. • Option to programme using the app for in-home control via Bluetooth connection (no Wi-Fi needed) or manual control via the thermostat.If you want Opentherm or eBus (and don't have Tado) then can just buy the "wired" kit from the start. There's no point faffing about buying a wireless kit and then buying the wired thermostat, when that is already in the wired kit! If you need to have a wireless setup then you can buy the EU version.Answer / Solution. Many Honeywell Home Programmable Thermostats provide OpenTherm control of applicable OpenTherm boilers. The following information should be considered when specifying these thermostats for OpenTherm Boilers. In particular, support for DHW setpoint. You would need to contact the boiler manufacturer to ascertain which device ...OpenTherm is a multi point to point communication protocol for use in residential heating. OpenTherm needs the same type of connection as in all modern installations, i.e. a 2-wire low voltage and polarity-free connection. In addition OpenTherm can also be used as a wireless protocol. The communication protocol describes the way digital ...HOW TO WIRE , NEST LEARNING THERMOSTAT INSTALLATION Step by step guide How to install the nest thermostat via Opentherm and on / off connection , Boiler plus...Your alternative is to buy an add-on wired thermostat, which has the digital connection which support OpenTherm. The wired thermostat is battery powered, so it does not need a mains power source, so you can locate it close to the boiler and then run a 2-core cable from it to the OpenTherm connection on the boiler. Once you have the wired ...New Boiler plus approved control Baxi 630 wi(these connections are not polarity specific so it does

Top Travel Destinations in 2024

Top Travel Destinations - Connecting Modulating OpenTherm thermostat The boiler is supplied w

Opentherm. Communication. Arduino library to send and receive data from Opentherm devices. Using this library and special hardware interface you will be able to create your own thermostat to control Opentherm boiler or build a man-in-the-middle gateway to capture or alter communication running between your thermostat and boiler. For detailed ...Enable OpenTherm serial output Enables OpenTherm commands dump to the serial (micro-USB) port. You can use OpenTherm Monitor software to monitor your setup. It allows you to inspect opentherm messages log and draw history graph to visualise system behavior. ... It would reset connection settings and restart a thermostat with its own Wi-Fi ...IMPORTANT - This video is intended exclusively for licensed mechanical contractors.The equipment referenced in this video may differ from the equipment being...OpenTherm (OT) is a standard communications protocol used in central heating systems for the communication between a central heating appliances and a thermostatic controller. As a standard, OpenTherm is independent of any single manufacturer.In order to connect your Arduino board to Opentherm device, you need to create a special hardware interface to convert voltage and current levels for Arudino to be able to handle. Voltage on Opentherm bus rises as high as 24V which would easily burn up your Arduino if connected to wires directly.There already was an app for OpenTherm GateWay, OTGW for short (many thanks for your work @nlrb!): OpenTherm Gateway App for Homey | Homey I tried to install it on my new Homey Pro 2023, but that was a no-go. Installing on my older Homey did work, but the connection was somewhat unstable, and the functionality was too heavy for my application.A quick and easy solution to an otherwise expensive problem. The valves have a 1⁄2" BSP (R1⁄2") tail piece connection to the radiator and are available with15mm, 10mm or 8mm compression fitting or an elbow with 15mm, 10mm push-fit fitting to connect the valve to the pipe workDownload this manual. VIESMANN. Operating instructions. for the system user. OpenTherm room temperature controller with digital time switch. For Vitodens 100-W, 111-W and 050-W. Room temperature controller. Please keep safe. 5837779 GB.Hello Herman, My setup uses the Nodo OpenTherm gateway (which now is version 2.3 hardware) and a NodeMCU for the WiFi connection. All documentation is on the website of the Nodo shop.Re-wiring to OpenTherm from the standard installation Any motorized valves need to be disconnected and set to open. Then follow steps 2-5 above to wire in the OpenTherm. ... Connection Charts. Always switch off the mains before removing the Wiser Heat HubR - and never fit it to a live wallplate! Make the wiring connections, as shown in the ...OpenTherm is a non-manufacturer-dependent system of communication between modulating HVAC heating appliances and room thermostats. It consists of a communication protocol and an interface specification. OpenTherm is a futuristic technology combining simple installation procedure with high functionality and future expansion possibilities.Opentherm connection3 Opentherm connection to the boiler is working correctly. 1 1 2 2 3 3 Battery replacement Batteries should operate for approximately 18 to 24 months. Only good quality alkaline batteries are to be used. If the batteries run out then central heating and hot water will continue to operateOpenTherm ( OT ) 是中央供暖系统中使用的标准通信协议,用于中央供暖锅炉和恒温控制器之间的通信。作为标准,OpenTherm 独立于任何单一制造商。原则上,制造商 A 的控制器可用于控制制造商 B 的锅炉。但是,OpenTherm 控制器和锅炉实际上并不总是一起正常工作。Are you a fan of the Atlanta Braves? If so, you’ll want to stay up to date with all the latest news and information about your favorite team. The official website of the Atlanta Br...OpenTherm es un lenguaje que los termostatos y sistemas de calefacción compatibles usan para comunicarse, lo que permite a los termostatos controlar los sistemas de calefacción y agua caliente de uso doméstico. Los siguientes termostatos Nest son compatibles con OpenTherm: Nest Thermostat E. Nest Learning Thermostat de 3.ª generación.10.3 OpenTherm BUS & ON / OFF connection (blue) This PCB will detect if an OpenTherm or an On / Off device is connected to the blue plug on the terminal block. An OpenTherm compatible device as well as a volt free on / off thermostat or programmable room thermostat can be used to switch on or off the heat demand to the boiler.Opentherm wired or wireless receiver? BOG73 . March 2022. There is any functionality difference in opentherm mode if the conection is made directly (wired) or wireless receiver? If wireless receiver is not used and therefore will not comand the boiler via opentherm but thermostat will do this by direct connection (wired) the opentherm protocol ...Provide TCP/IP relay server to allow other OpenTherm monitor software connection by this instance (when direct USB connection is used) Where possible, adjust values in ioBroker and send command to Opentherm; Please feel free to add feature requestsThe documentation tells that ID is explained as: The gateway_id for this OpenTherm Gateway's entity IDs and services. The entered value will be slugified. I have no idea what that is. Or is it that 'name' is not the prefix for the entities? Ok, then the introduction text of the add integration dialog could be perhaps something like this:There already was an app for OpenTherm GateWay, OTGW for short (many thanks for your work @nlrb!): OpenTherm Gateway App for Homey | Homey I tried to install it on my new Homey Pro 2023, but that was a no-go. Installing on my older Homey did work, but the connection was somewhat unstable, and the functionality was too heavy for my application.OpenTherm Monitor Home Assistant supervisor add-on - basnijholt/addon-otmonitorLV connections X 3.1 - X 3.2 Flow temperature sen-sor for heating circuit without mixer (immer-sion temperature sen-sor) X 3.3 - X 3.4 OpenTherm connec-tion of boiler control unit X 12.1 - X 12.2 OpenTherm room tem-perature controller for heating circuit with mixer X 12.3 - X 12.4 OpenTherm room tem-perature controller for heating circuit ...Hi, I have changed my boiler by a Baxi Compact Platinum which supports OpenTherm (OT). Additionally, for power eficiency, I bought the modular thermostat TXM 10c which can connect with the Baxi phone app to control and monitoring remotely. This is the TXM 10c thermostat and comes with a OpenTherm gateway (GTW-16): and …Just added Opentherm connections (combi-boiler). Do I need to reset the system to recognise the new Opentherm connections? Thermostat Hi All I just this afternoon installed a Nest 3rd gen. After a couple of hours of use, I additionally connected the OT1 and OT2 connections to the heat link (my combi-boiler supports OpenTherm). ... Use OpenTherm ...I am using home assistant for my thermostat function with multiple zones, using the generic thermostat integration. My objective is to expand this with OpenTherm functionality rather than just on/off as my combination boiler can handle OpenTherm too. I bought the Opentherm module from Ihormelnyk.com, by Ihor Melnyk. He has written documentation on his website for a the integration in HA with ... 7,8 OpenTherm bus monitor, slave connection V,gn